đź§Ş Inspection, Testing & Maintenance
Because Problems Don’t Fix Themselves
“How do I know my electrical system’s actually safe?”
“Is my wiring up to code, or a fire hazard waiting to happen?”
“What’s really going on behind my walls?”
Most electrical problems don’t announce themselves—they sit quietly in the background, getting worse by the day. Then suddenly… they cost you thousands in damage, downtime, or worse.
At JMS Electrical, we don’t wait for things to break. We find the issues before they become problems.
That’s what our Inspection, Testing & Maintenance service is all about—keeping your system healthy, safe, and reliable, 24/7.
Electrical Testing Services Power Quality Analysis
Power Quality & Efficiency
Power Quality & Efficiency |
---|
Voltage sags/swells/dips/unbalance |
Harmonic distortion analysis (THD, individual harmonics) |
Transient voltage capture and analysis |
Flicker measurement and compliance |
Power factor and reactive power assessment |
Load studies and demand analysis |
Energy efficiency evaluations |
Compliance testing (IEEE 519, IEC 61000) |
Mitigation solutions (filters, compensators) |
Infrared & Thermography
Infrared & Thermography |
---|
Infrared Electrical Inspections |
Electrical panel and switchgear thermography |
Transformer and bus connection scans |
Motor and drive thermal imaging |
Cable termination and joint inspections |
Fuse and breaker temperature analysis |
Solar farm electrical inspections |
Electrical Testing & Diagnostics
Electrical Testing & Diagnostics |
---|
Insulation Testing |
Megger testing (low/medium/high voltage) |
Polarization Index (PI) and DAR testing |
HiPot (dielectric withstand) testing |
Transformer insulation testing |
Motor and generator winding tests |
Cable insulation integrity testing |
 |
Circuit Breaker Testing |
Contact resistance measurements |
Trip timing and characteristics testing |
Insulation resistance testing |
Mechanical operation analysis |
Dynamic contact resistance (DCR) |
Partial discharge detection |
 |
Ground System Testing |
Fall-of-Potential (3-point) testing |
Soil resistivity measurements |
Step and touch potential analysis |
Ground grid integrity verification |
Clamp-on ground resistance testing |
Tower and lightning ground testing |
Neutral-to-ground voltage checks |
 |
Transformer Testing |
Turns ratio (TTR) testing |
Dissolved gas analysis (DGA) |
Power factor/dissipation factor |
Winding resistance measurements |
Sweep frequency response analysis |
Insulation resistance testing |
 |
Motor Testing |
Motor circuit analysis (MCA) |
Surge comparison testing |
Insulation resistance testing |
Rotor bar defect detection (incomplete item, please verify) |
🧠Why You Can’t Ignore This Stuff
Think of your electrical system like your car. If you don’t inspect it, test it, and service it—it fails when you least expect it.
Here’s what neglecting electrical maintenance can cost you:
Surprise outages
Damaged equipment
Fire risk
Failed inspections
Insurance problems
Expensive emergency repairs
You don’t want that. And you don’t need it. That’s why preventative care always wins.
Â
Â

We don’t just “look around.” We perform detailed inspections and certified testing that catch the stuff most people miss.
Our services include:
Full electrical safety inspections
Load testing & balancing
Thermal imaging to detect overheating components
Grounding & bonding checks
Circuit and breaker testing
Surge protection evaluation
Compliance inspections (for local code, NEC, OSHA, etc.)
Maintenance for panels, switchgear & emergency systems
Test reports + written documentation for your records
Whether it’s your home, office, warehouse, clinic, or commercial unit—we tailor the testing to your setup.
Sometimes you just need a one-time inspection before buying, selling, or renovating.
Other times, you want routine maintenance to catch issues before they break something.
We offer:
One-off inspections
Annual testing plans
Quarterly preventative maintenance
Custom contracts for commercial & healthcare facilities
With JMS Electrical, you’re not locked into anything. You get what you actually need. That’s it.
One of our commercial clients was dealing with random system shutdowns. Their old electrician said “everything looks fine.”
We did a full thermal scan. Turns out a single breaker was overheating under load—and on the verge of failure. Swapped it out same day. Problem solved. No downtime. No disaster.
That’s what proper testing catches.
If you’re seeing (or hearing) any of this, it’s time to call:
Lights flickering without reason
Burning smell near panels or outlets
Breakers tripping regularly
Unexplained power loss in part of the building
Buzzing or crackling sounds from panels
Your electrical setup hasn’t been checked in over 2 years
These aren’t “minor annoyances.” They’re warning signs.
We don’t just inspect. We explain. You’ll know exactly what’s working, what’s not, and what to do next.
We use the right tools. Thermal scanners, load testers, and diagnostic gear—not just flashlights and guesswork.
We build reports that help you plan. Maintenance schedules, risk flags, upgrade suggestions—clear and to the point.
We’re licensed, insured, and experienced. No corner cutting. Ever.
Electrical issues don’t usually scream. They whisper—until something breaks, overheats, or sparks out. If it’s been more than a year since your last inspection… you’re already overdue.
Let’s fix that.
Book an inspection or set up a maintenance plan with JMS Electrical today.